48V 4000i & 5500i
Technical Specifications
MODEL HAUS STROM Series | HPSW 4000i | HPSW 5500i | |
---|---|---|---|
VOLTAGE LIMITS NARROW WINDOW(UPS MODE) | |||
Mains A.c Low Cut | 180±10V | 180±10V | |
Mains A.C Low Cut Recovery | 9-12V Hysterisis from >Low Cut Voltage |
9-12V Hysterisis from >Low Cut Voltage |
|
Mains A.C High Cut | 260±10V | 260±10V | |
Mains A.C High Cut Recovery | 9-12V Hysterisis from < High Cut Voltage |
29-12V Hysterisis from < High Cut Voltage |
|
VOLTAGE LIMITS WIDE WINDOW(W-UPS MODE) | |||
Mains A.C Low Cut | 100±10V | 100±10V | |
Mains A.C Low Cut Recovery | 9-12V Hysterisis >LowCut Voltage |
9-12V Hysterisis >Low CutVoltage |
|
Mains A.C High Cut | 280±10V | 280±10V | |
Mains A.C High Cut Recovery | 9-12V Hysterisis < HighCut Voltage |
9-12V Hysterisis < HighCut Voltage |
|
OUTPUT PARAMETER | |||
Mains Output | Same as Input (45Hz-55Hz) | ||
Output Frequency | 50Hz±1Hz | 50Hz±1Hz | |
Output Voltage With Full Load | 177-220V | 177-220V | |
Waveform | Sine Wave | Sine Wave | |
Overload | Above 100% | Above 100% | |
Short Circuit Protecon | >200% | >200% |
MODEL HAUS STROM Series | HPSW 4000i | HPSW 5500i |
---|---|---|
BATTERY CHARGING | ||
Closed Loop Auto Sensing Sftoware Control(ASSC) Charging Technology with over full range of Mains | ||
Battery type | SMF/TUBULAR/Flooded LEAD ACID (Selectable ) | |
Charging Current | 18A/13A(Selectable) | 24A/12A(Selectable) |
Recommended Baery Capacity | 100-200AH | 100-200AH |
Number of Baeries | 4 | |
TECHNOLOGY | ||
Pure Sine Wave Technology using PWM Topology Closed Loop Auto Sensing Soware Control(ASSC) Smart Power Storage Charging Technology for Longer Power Storage Life |
||
Storage Temp. | 0-50˚C | 0-50˚C |
Humidity | 90%Non -Condensing | |
Dimension (WXDXH) in mm | 000x000x000mm | 000x000x000mm |
ALL GENERATORS COMPATIBLE
Haus Strom Inverter can charge batteries with power provided by all kinds of generators local or company made. Wide window of frequency range between 45-55Hz makes totally compatible with all local generators.
TRUE GALVANIC ISOLATION
Fundamental frequency transformer is used for low frequency isolation at the grid side. It provides safety to equipment against power surges & transients.
COMPATIBLE WITH WIDEST RANGE OF BATTERIES
Haus Strom inverter 5 KVA / 48 V is able to charge batteries of all sizes. This feature give you the flexibility to buy the battery that is suited to your background.
BYPASS FEATURE
Incase of maintenance of the battery/failure of Haus Strom Inverter or during the servicing of the UPS, the costumer himself can directly switch to the mains by a simple twist of a switch, and will not need any electrician to remove any wires from the inverter.